Safety valve 1"1/4 pressure up to 300 mbar pozice 2
Code: VL1.2ALRelated products
Single-stage pump, which can also be used as an air blower max. 60 m3/hr, max. 100 mbar, -100 mbar 1 channel, 0,25 kW, 230V 1-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 70 m3/hr, max. 120 mbar, -110 mbar 1 channel, 0,25 kW, 400V 3-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 80 m3/hr, max. 110 mbar, -110 mbar 1 channel, 0,4 kW, 230 V 1-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 80 m3/hr, max. 110 mbar, -110 mbar 1 channel, 0,4 kW, 400 V 3-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 270 m3/hr, max. 120 mbar, -140 mbar 1 channel, 1,5 kW, 230V 1-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 145 m3/hr, max. 160 mbar, -160 mbar 1 channel, 0,85 kW, 400V 3-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 145 m3/hr, max. 160 mbar, -160 mbar 1 channel, 0,85 kW, 400V 3-phase. For the safe operation of the pump-blower,...
Single-stage pump, which can also be used as an air blower max. 145 m3/hr, max. 160 mbar, -160 mbar 1 channel, 0,85 kW, 400V 3-phase. For the safe operation of the pump-blower,...
Product detailed description
Accessories for Blower (BLOWERS)

Vacuum accessories (EXHAUSTERS)

Additional parameters
| Category: | Příslušenství vývěvy Dmychadla |
|---|---|
| Warranty: | 0 |
| Weight: | 2 kg |
| Materiál: | Hliník |
| Tlak: | 0 až 300 mbar |
| ? Připojení vnější závit: | 1"1/4 - 1"1/2 m |
| Pozice: | 2 |
The hose connects the pump to other equipment and reduces vibration and machine temperature. Hose length 1 m.
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
Plastic elbow 2"1/2 female thread, PVC 150 mm - pos.6
The hose connects the pump to other equipment and reduces vibration and machine temperature. Hose length 1 m.
Fine tube diffusers are used in wastewater treatment, sludge aeration, drinking water treatment, fish farming, aquarium farming, etc. It is the discharge and dispersion of...
Filter for Blower 1"1/4, 100 µm, pos. 9
Safety relief valve, position 2. The safety valve protects against the risk of overpressure at the blower and underpressure at the vacuum pump. Reduces the operating pressure to...
The valve functions as a double vacuum/vacuum breaker with a central common threaded connection, pneumatically actuated by a double acting cylinder; thus it has 2 flat ports, 3...
It is used to prevent backflow, especially during the start and stop of the blower. Flap pos.12 must be installed at the outlet.
PVC plastic nipple, pos. 6
Safety relief valve, position 2. The safety valve protects against the risk of overpressure at the blower and underpressure at the vacuum pump. Reduces the operating pressure to...
Filter for Blower 1"1/2, pos. 5 These filters are commonly installed on the suction side of side channel blowers and compressors to protect them from dust and solids that could...
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
PVC plastic nipple, pos. 6
Safety relief valve, position 2. The safety valve protects against the risk of overpressure at the blower and underpressure at the vacuum pump. Reduces the operating pressure to...
Safety relief valve, position 2. The safety valve protects against the risk of overpressure at the blower and underpressure at the vacuum pump. Reduces the operating pressure to...
