Membrane diffuser 12.5" Silicone, 3/4" M
Code: BLDD12SNProduct detailed description
The activated sludge process is the main stage of modern technology for wastewater treatment. The key is to ensure sufficient oxygen in the activated sludge process and to keep the slurry and solids in suspension.


Additional parameters
| Category: | Příslušenství vývěvy Dmychadla |
|---|---|
| Warranty: | 6 měsíců |
| Weight: | 0.93 kg |
| Materiál: | Polypropylen 70% a 30% skleněné vlákno |
| Materiál membrány: | Silikon |
| Průměr: | 12,5" |
| ? Připojení vnější závit: | 3/4" M BSPP |
| Umístění : | Výtlak |
| ATEX certifikát: | NE |
| Effective-Total Lenght: | 340 -370 mm |
| Efektivní oblast: | 0,07 m2 |
| Množství : | 2 až 12 m3 |
PVC plastic nipple, pos. 6
Filter for Blower 2" 1/2, pos. 5 These filters are commonly installed on the suction side of side channel blowers and compressors to protect them from dust and solids that could...
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
Filter for Blower 3", pos. 5 These filters are commonly installed on the suction side of side channel blowers and compressors to protect them from dust and solids that could...
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
Filter for Blower 1"1/2, pos. 5 These filters are commonly installed on the suction side of side channel blowers and compressors to protect them from dust and solids that could...
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
Safety relief valve, position 2. The safety valve protects against the risk of overpressure at the blower and underpressure at the vacuum pump. Reduces the operating pressure to...
It is used to prevent backflow, especially during the start and stop of the blower. Flap pos.12 must be installed at the outlet.
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...
Filter for Blower 1"1/4, pos. 5 These filters are commonly installed on the suction side of side channel blowers and compressors to protect them from dust and solids that could...
The hose connects the pump to other equipment and reduces vibration and machine temperature. Hose length 1 m.
It is used to prevent backflow, especially during the start and stop of the blower. Flap pos.12 must be installed at the outlet.
The hose connects the pump to other equipment and reduces vibration and machine temperature. Hose length 1 m.
The valve functions as a double vacuum/vacuum breaker with a central common threaded connection, pneumatically actuated by a double acting cylinder; thus it has 2 flat ports, 3...
Filter on the suction line of the vacuum pump to create vacuum, paper filter 5÷7, position 4. These filters are normally installed in the pump intake to protect it from dust and...